ASSESSMENT & DEPLOYMENT PATHWAYS
Multi-Dimensional Structured Database of Green Building Technologies
This is a systematically assembled, structured database covering building envelope and system technologies relevant to Hong Kong—including exterior walls, insulation, façade paints, windows, lifts, and HVAC options. For each technology, the database records not only technical performance and cost, but also environmental and social attributes, as well as its current or potential availability in Hong Kong. It provides the knowledge base for later participatory work with policymakers, industry, and building users.
Holistic Assessment Framework and Technology Map
This framework evaluates green building technologies across four working dimensions—technical, economic, environmental, and social—by combining a desk-based literature and code review with structured expert surveys and semi-structured interviews. The resulting technology map shows where expert opinion aligns with or diverges from theoretical assessments. For example, technologies such as green roofs, low-e glazing, and elevator LED retrofits achieve high consensus, whereas phase-change reflective coatings and super-capacitor elevators show notable disagreement, revealing practical barriers not captured in the literature.
Policy and Regulatory Gap Analysis Report
This report systematically reviews Hong Kong’s Buildings Ordinance, energy efficiency ordinances, and green building certification frameworks (BEAM-PLUS and LEED). It identifies structural biases—for instance, envelope and HVAC measures receive strong regulatory support, while more regenerative options like building-integrated photovoltaics or phase-change façade systems gain little explicit recognition and struggle to enter mainstream projects. It also highlights misalignments between what codes count and what matters on the ground, such as the lack of social criteria like maintenance burden in ageing public estates, offering a clear direction for future policy refinement.
| Initial Assessment | Mean of Expert Questionnaire | Standard Deviation of Expert Questionnaire | Expert Questionnaire Deviation from Initial Assessment | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Category | Technology | Economic | Environment | Social | Economic | Environment | Social | Economic | Environment | Social | Economic | Environment | Social |
| Paints | PRCP | 4.5 | 4.5 | 4.5 | 4 | 3.83 | 3.67 | 1 | 1.07 | 1.11 | 0.5 | 0.67 | 0.83 |
| Paints | Thermal Insulating Paints | 2.5 | 3 | 3 | 3.17 | 3.33 | 3 | 0.69 | 0.47 | 0.58 | 0.67 | 0.33 | 0 |
| Windows | Single Glazed Windows | 2.5 | 2 | 2 | 5 | 3.5 | 4 | 0 | 0 | 0.5 | 2.5 | 1.5 | 2 |
| Insulation Material | Aerogels | 1.5 | 3 | 2 | 2.75 | 3 | 3 | 0.43 | 0 | 0 | 1.25 | 0 | 1 |
| Lifts | Regenerative Power Devices | 5 | 4 | 4 | 4 | 3.67 | 3.33 | 0 | 0.47 | 0.94 | 1 | 0.33 | 0.67 |
| Lifts | Super-Capacitor Elevators | 3 | 5 | 3 | 2 | 2.67 | 2.67 | 0 | 0.47 | 0.47 | 1 | 2.33 | 0.33 |